Lefilter2024-01-05 BACK TO LIST
Filtration process: Dust-laden air is sucked in from the primary coarse filter box ① by the air compressor, and passes through the high-efficiency
filter cartridge ②. Due to the comprehensive effects of gravity inertia, diffusion, contact retention, etc., the dust is adsorbed on the high-efficiency
filter cartridge , the clean air enters the Venturi tube ④ through the sealing gasket ③, goes to the clean air chamber ⑤ and merges into the air
collection port ⑥, and is then sucked into the air compressor from the clean air outlet pipe ⑦.
Self-cleaning process: After the dusty air is filtered, the dust is adsorbed on the high-efficiency filter cartridge, and the PLC performs the backflush
self-cleaning process according to the set time sequence. When the resistance loss value exceeds 600 Pa, the PLC controls it according to the
differential pressure sequence. During the backflush self-cleaning process (backflush time is 0.1 seconds), other high-efficiency filter cartridges
work as usual, and dust is blown back and self-cleaned.